Products:
Unfired: PHWS
Model PHWS Packaged Hot Water Generator
Specification
1. General
Furnish and
install as shown on the plans one (1) PRECISION model PHWS-H
horizontal (or -V, vertical) packaged hot water generator. Generator
shall provide _____gallons per hour of potable water at 140 F when
supplied with city water at_____ F and steam at____psig (boiler
water at ____ F). Heater storage section shall have a diameter of
_____inches, a capacity of ____gallons and shall be designed for 125
psig. Packaged generator shall be completely factory assembled with
controls and trim as specified below.
2. Pressure Vessel
Vessel shall be
constructed and stamped in accordance with ASME Section IV HLW and
shall be registered with the National Board. Shell shall be
fabricated from carbon steel, with integral 12" by 16" manway, and
shall be furnished with [choose one of]:
"Precision Seal"
polymerized epoxy lining with carbon steel fittings and 5 year
manufacturer's limited warranty [max temp 1600 F].
"Coppercoat" TM
lining with carbon steel fittings and 10 year manufacturer's limited
warranty [max temp 1600 F].
"Nickelcoat"
lining with carbon steel fittings and 1 0 year manufacturer's
limited warranty [max temp 1600 F].
Aluminum silicate
cement lining with 304 stainless steel fittings and 10 year
manufacturer's limited warranty [max temp 2100 F].
All fittings,
nozzles and joggled joints shall be seal welded internally to
eliminate crevices between pressure boundary parts. Storage vessel
shall be fitted with a removable Utube heating coil with
non-ferrous tubesheet and separator. Tubes shall be (select one of):
-
3/4" OD single
wall seamless SB75 copper tubes with 20 BWG [0.035"] wall.
-
3/4" OD single
wall seamless SB111 cupro-nickel tubes with 20 BWG [0.035"]wall.
-
3/4" OD single
wall SA240-304 stainless steel tubes with 20 BWG [0.035"] wall.
-
3/4" OD single
wall SA240-316 stainless steel tubes with 20 BWG [0.035"] wall.
-
3/4" OD double
wall, seamless SB75 copper tubes with integral leak detection
passages.
Heating capacity
of coil shall be ____GPH at ____ F to ____ F temperature rise using
steam at ____ psig inlet pressure to control valve. (Water at ____ F
inlet temperature and ____psig pressure to control valve.)
3. Steam-to-Water
Generator Controls
Steam-to-water generator shall be provided with the following
controls: Factory installed steam control valve with steam capacity
of______Ib/hr at _____ psig inlet pressure to vary the flow of steam
to the heating coil in response to variations in storage tank
temperature. Control valve shall be self contained, self-operating
(pneumatic, diaphragm actuated, spring to close in event of air
failure.) (pilot-operated)(electric actuated) with upstream
strainer. Trim shall include properly sized ASME
pressure-temperature relief valve, manual drain valve, water
thermometer and pressure gauge, all tank mounted; float and
thermostatic steam trap on coil outlet and auxiliary steam trap on
upstream side of control valve, both piped to common condensate
outlet; and (vacuum breaker on tank coil cap).
4. Water-to-Water
Generator Controls
Water-to-water
generator shall be furnished with the following controls: Factory
installed heating water 2-way or 3-way diverting control valve with
water capacity of _____GPM at inlet temperature of _____ F to vary
the flow of heating water to the coil, in response to variations in
storage tank temperature. Control valve shall be self contained,
self operating (pneumatic, diaphragm actuated, spring-to-close in
event of air failure)(electric actuated) with upstream strainer.
Trim shall include properly sized ASME pressure-temperature relief
valve, water thermometer, water pressure gauge and manual drain
valve, all tank mounted; (heating water pressure gauge) (heating
water inlet/outlet temperature gauges)(high temperature cutout).
5. Integral
Circulation System
Provide baffled
heating coil with wrapper and bronze circulator, factory piped with
copper tubing and bronze-bodied isolating ball valves.
6. Packaging
Complete package
shall be factory assembled and mounted on structural channel support
skid. All specified components are to be mounted, piped (and wired).
Tank shall be insulated with 2 inches of heavy duty fiberglass to
conform to ASHRAE 90.1 and housed in a rectangular, 16 gauge enamel
painted steel jacket. Lift lugs shall be provided to allow rigging
of package during installation.
7. Quality Control
Complete packaged
generator shall be manufactured by PRECISION Boilers, LLC in strict
accordance with ASME Boiler and Pressure Vessel Code and ISO 9002
Quality Standard.
Specifications subject to change without notice.
|