Products:
Electric: PCW
Model PK Packed Column Deaerator
Specification
Furnish and
install as one Packed Column Deaerating Heater as designed and
manufactured by Precision Boilers. Deaerator shall be model number
___________ and shall consist of the following:
(1)
Basic:
_____PPH Packed Column Type Deaerator with a capacity of _____ gallons
to overflow (______ minutes of storage). Storage vessel shall be
______ diameter by ______ shell length (not including heads) and shall
be constructed in accordance with the ASME code (latest revision).
Deaerator shall include connections as follows: water inlet ____,
steam inlet______, pump suction ______, overflow________, relief valve
and vacuum breaker (common)_______, vent ______, vessel drain
______,thermometer________, pressure gauge_______, access openings and
all water level instrumentation equalizing connections required for
operation (minimum of four). Each pump suction shall be equipped with
a vortex breaker which must be constructed as follows: cross plate
design of ¼” material and dimensionally two times greater than the
nozzle diameter (minimum). Deaerator shall operate at all flows with a
20:1 turndown ratio, shall deaerated the water so that the oxygen in
the effluent leaving the deaerator storage tank shall not exceed .005
cc/liter as determined by the Heat Exchange Institute method, Winkler
method, or any other leading testing method approved by ASTM, and
shall reduce the titratable free CO2 to zero as determined by the APHA
testing method. The Packed Column deaerator shall have spray valves
which shall be Type 316 stainless steel, be non-binding, and have a
guide bar. Deaerator column shall by Type 304 stainless steel ¼”
thick minimum, and shall be equipped with a flanged access for ease of
packing inspection and removal. Packing Rings shall be constructed of
stainless steel. Operation shall be of the counterflow design; water
shall enter vent condenser, go through spray valves and cascade
downward through packing rings while the steam will enter through the
bottom of the column, moving upwards through the packing rings. The
result of the counterflow operation will be fully Deaerated Water
exiting the column section into the storage section.
(2) Operating Conditions:
Returns: Low Temp (<227º F) _____%@_____ ºF
High Temp (>227º F) _____%@_____ ºF
Make-Up: _____PSIG _____%@_____ ºF
(3) System Components:
Other integral and necessary components shall be per specification and
shall include instruments (sight, temperature and pressure gauges, and
level and pressure controls); level control valve (mechanical,
electric, electro-pneumatic, pneumatic); feedpump(s) (turbine,
multi-stage centrifugal, etc.); overflow drainer; vacuum breaker;
relief valve (sentinel or full capacity); pump suction stop valve,
strainer and vibration isolator; pump discharge stop valve, check
valve, bypass orifice or relief valve, pressure gauge, etc.;
NEMA____UL-Labeled control cabinet to include necessary pilot lights,
switches, control transformer, disconnects, starters, logic relays,
etc.
Specifications subject to change without notice.
|
   
|
|